An older version of the experimental database is currently selected, click here to switch to the latest
You need a browser with JavaScript support in order to view the molecule in 3D
uid 305

TransitionsLeft-clk & drag: Zoom; Right-clk: reset

This species has a counterpart in the theoretical library

Transitions

Frequency
[wavenumbers]
Wavelength
[microns]
Integrated cross-section
[km/mol]
3129 3.196 1.61
3092 3.234 36.56
3062 3.266 45.26
3045 3.284 56.51
3014 3.318 16.22
2985 3.35 1.76
2974 3.362 0.89
2296 4.354 0.48
2200 4.545 0.27
1948 5.134 1.38
1944 5.144 2.07
1942 5.148 1.12
1932 5.175 0.45
1917 5.216 3.41
1913 5.227 1.12
1912 5.231 0.59
1902 5.257 0.69
1885 5.306 1.61
1850 5.406 0.78
1833 5.455 1.67
1824 5.482 0.89
1803 5.546 2.12
1778 5.625 3.94
1772 5.645 3.86
1759 5.685 8.97
1748 5.72 1.19
1744 5.734 1.48
1702 5.874 1.22
1683 5.942 2.1
1668 5.993 0.79
1528 6.544 2.14
1519 6.584 12.35
1495 6.688 14.27
1458 6.857 17.14
1433 6.978 14.55
1353 7.393 4.08
1335 7.493 1.97
1283 7.794 2.88
1269 7.878 5.04
1226 8.155 10.54
1220 8.199 2.89
1213 8.242 2.63
1172 8.53 3.88
1047 9.549 4.34
1038 9.638 3.01
962.4 10.39 2.02
945.2 10.58 3.18
889.3 11.24 33.26
879.8 11.37 1.31
861.6 11.61 1.31
802.9 12.45 46.23
776.7 12.87 1.06
767 13.04 2.66
743.2 13.46 53.44
709.6 14.09 7.51
648.8 15.41 3.24
591.9 16.89 10.61
556.2 17.98 3.01
493.1 20.28 2.35
432.7 23.11 5.71

Laboratory Spectrum

LabLeft-clk & Shift: drag to zoom; Left-clk + Ctrl: Pan; Right-clk: Reset.

This spectrum was measured using the matrix isolation technique. Samples are prepared by co-deposition of the PAH in the gaseous state with an overabundance of argon onto a cold CsI window suspended in a high vacuum chamber (p ~ 10-8 mtorr). The CsI window temperature is held between 10 and 15 K for the duration of the experiment. The infrared spectrum of the cold CsI window is recorded prior to (I0) and immediately after sample deposition (In). The absorbance spectrum for a neutral, matrix isolated PAH is log(In/I0).

By irradiating this matrix with ultraviolet radiation from a microwave powered hydrogen discharge lamp produces ionized PAHs. The infrared spectrum is again measured (Ii), now having absorption bands due to both the neutral and ionized PAH. This absorbance spectrum (log (I/Ii)) is compared with that of the neutral PAH. Most of the new bands produced by ultraviolet irradiation are due to the ionized form of the PAH. See the provided reference for the specific details regarding the data presented here. In some cases a few bands near 1600 cm-1 may be due to H2O.

Note(s):


You are kindly asked to consider the following references for citation when using the database:


84 species present in version 3.00 of the experimental database (Apr 16, 2020)